HPE Nimble Storage - All Flash Only
Scheduled Maintenance Report for Servers Australia
Completed
The scheduled maintenance has been completed.
Posted May 09, 2024 - 03:00 AEST
In progress
Scheduled maintenance is currently in progress. We will provide updates as necessary.
Posted May 09, 2024 - 01:00 AEST
Scheduled
To improve stability and security, we will be updating all HPE Nimble storage all-flash devices to the latest firmware during this maintenance window.

The HPE nimble devices have dual controllers, which will be done one at a time. During this time the controllers will fail-over. There will not be any impact to customer workloads as long as correct timeouts are set on the iSCSI connections.

Please see below to confirm you have the correct iSCSI timeout values set.

For windows, if you use the HPE Nimble toolkit to connect to the volumes, the correct timeout values will already be set and no action is required.

Windows:
https://infosight.hpe.com/InfoSight/media/cms/active/public/pubs_NimbleOS_5.0.x_Help.whz/wbi1486590879561.html

VMware/ESXi:
LoginTimeout – 30 seconds (default is 5 seconds)
NoopTimeout – 30 seconds (default is 10 seconds)
NoopInterval – 30 seconds (default is 15 seconds)

Linux:
LoginTimeout – 30 seconds
NoopTimeout – 30 seconds
NoopInterval – 30 seconds

If you're unsure, please feel free to reach out to our support team to assist you.
Posted May 02, 2024 - 14:18 AEST
This scheduled maintenance affected: Services (Network Storage).